Vulnerability feed
CVE and vendor PSIRT advisories from 13 sources, last 30 days. Updated hourly, last run
| Expand | Severity |
Score |
Advisory |
Title |
Source |
Flags |
Published |
|---|---|---|---|---|---|---|---|
| Low | 2.9 | CVE-2026-115797 |
A weakness has been identified in Tenda F6 12.02.01.73
TendaTenda F6
|
NVD | |||
|
CVE-2026-115797A weakness has been identified in Tenda F6 12.02.01.73
From the advisoryA weakness has been identified in Tenda F6 12.02.01.73. Affected is an unknown function of the component Web Management Interface. Executing a manipulation of the argument ecos_pw can lead to cleartext transmission of sensitive information. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is told to be difficult. The exploit has been made available to the public and could be used for attacks. Impact if exploitedConfidentialityLow IntegrityNone AvailabilityNone
How it is exploited
CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Affects
NIST National Vulnerability DatabasePublished
Read the advisory
|
|||||||
| Low | 2.1 | CVE-2026-115796 |
A security flaw has been discovered in Tenda F6 12.02.01.73
TendaTenda F6, Tenda F6 (N300) Wireless Router
|
NVD | |||
|
CVE-2026-115796A security flaw has been discovered in Tenda F6 12.02.01.73
Executive summaryA security flaw in the Tenda F6 (N300) wireless router firmware V12.02.01.73 lets an attacker who tricks a logged-in administrator into opening a malicious web page perform administrative actions on the router, such as a factory reset, reboot, or password change. The advisory rates it High with a CVSS 3.1 base score of 8.0 and says the vendor had not responded when the report was written. The advisory does not state a vendor fix or recommended update; it lists remediation steps for the vendor to implement. Technical summaryThe flaw is a cross-site request forgery (CWE-352) in the router's web management interface, which accepts state-changing POST requests to /goform/ endpoints without anti-CSRF tokens or SameSite cookie restrictions. The attack requires an authenticated administrator to open an attacker-controlled page while on the device's network; the advisory gives a CVSS vector of AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Affected version is stated as Firmware V12.02.01.73 (Hardware V5.0), and the latest version at disclosure is stated as V12.02.02.77, which the researchers did not test. The advisory does not state a fixed version, and it does not state any workaround beyond the vendor remediation steps (anti-CSRF tokens, SameSite cookies, re-authentication for sensitive actions, and removing the recoverable Wi-Fi password from configuration downloads). Detection guidance is not stated. Summaries are generated by AI from the linked advisory text. Confirm versions and fixes at the source. Summarized from github.com/0xWKZER/tenda-f6-vulnerabili…blob/main/01-csrf.md Impact if exploitedConfidentialityNone IntegrityLow AvailabilityNone
How it is exploited
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Affects
NIST National Vulnerability DatabasePublished
Read the advisory
|
|||||||
| High | 8.6 | CVE-2026-114268 |
A flaw has been found in Tenda BE3L Pro 16.03.60.62
TendaTenda BE3L Pro
|
NVD | |||
|
CVE-2026-114268A flaw has been found in Tenda BE3L Pro 16.03.60.62
Executive summaryA buffer overflow flaw has been reported in the Tenda BE3L Pro router, firmware version V16.03.60.62. The advisory says the flaw can be triggered without logging in and can lead to crashes, memory corruption, or arbitrary code execution. The advisory says the issue requires immediate remediation, but it does not state a vendor-released fix. Technical summaryThe flaw is a stack-based or memory buffer overflow caused by an unchecked strcpy call in the formWifiBasicSet() function, reached through the /goform/WifiBasicSet endpoint. The security_5g POST parameter is copied into a fixed 256-byte buffer without a size check, and the advisory's proof of concept sends 2048 bytes. The advisory states no authentication is required. Affected version is listed as V16.03.60.62, and a fixed version is not stated. No vendor patch, workaround from the vendor, CVSS score, or exploitation in the wild is stated. The advisory's suggested repairs are developer-side code changes such as strncpy and bounds checking, and no detection guidance is given beyond these. Summaries are generated by AI from the linked advisory text. Confirm versions and fixes at the source. Summarized from github.com/Tmzop/Tenda-CVE Impact if exploitedConfidentialityHigh IntegrityHigh AvailabilityHigh
How it is exploited
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Affects
NIST National Vulnerability DatabasePublished
Read the advisory
|
|||||||
| Critical | 9.3 | CVE-2026-113744 |
A security vulnerability has been detected in Tenda AC19 16.03.10.07
TendaTenda AC19
|
NVD | |||
|
CVE-2026-113744A security vulnerability has been detected in Tenda AC19 16.03.10.07
From the advisoryA security vulnerability has been detected in Tenda AC19 16.03.10.07. The impacted element is the function formSetFirewallCfg of the file /goform/SetFirewallCfg of the component httpd Web Management Service. Such manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. Impact if exploitedConfidentialityHigh IntegrityHigh AvailabilityHigh
How it is exploited
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Affects
NIST National Vulnerability DatabasePublished
Read the advisory
|
|||||||
| High | 8.6 | CVE-2026-105778 |
A vulnerability has been found in Tenda AC5 02.03.01.111_multi
TendaTenda AC5
|
NVD | |||
|
CVE-2026-105778A vulnerability has been found in Tenda AC5 02.03.01.111_multi
From the advisoryA vulnerability has been found in Tenda AC5 02.03.01.111_multi. Affected by this issue is some unknown functionality of the file /goform/setWifi of the component Wifi Handler. Such manipulation of the argument wifiPwd leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Impact if exploitedConfidentialityHigh IntegrityHigh AvailabilityHigh
How it is exploited
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Affects
NIST National Vulnerability DatabasePublished
Read the advisory
|
|||||||
| High | 8.5 | CVE-2026-104611 |
A vulnerability was detected in Tenda AC9 15.03.02.13
TendaTenda AC9
|
NVD | |||
|
CVE-2026-104611A vulnerability was detected in Tenda AC9 15.03.02.13
From the advisoryA vulnerability was detected in Tenda AC9 15.03.02.13. Affected is an unknown function of the file /goform/fast_setting_internet_set of the component POST Request Handler. Performing a manipulation of the argument netWanType results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used. Impact if exploitedConfidentialityHigh IntegrityHigh AvailabilityHigh
How it is exploited
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Affects
NIST National Vulnerability DatabasePublished
Read the advisory
|
|||||||
| Critical | 9.3 | CVE-2026-104610 |
A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon
TendaTenda HG7, Tenda HG9, Tenda HG10
|
NVD | |||
|
CVE-2026-104610A security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon
From the advisoryA security vulnerability has been detected in Tenda HG7, HG9 and HG10 300001138_en_xpon. This impacts the function boaGetVar of the file /boaform/formLoopBack of the component Boa Web Server. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used. Impact if exploitedConfidentialityHigh IntegrityHigh AvailabilityHigh
How it is exploited
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Affects
NIST National Vulnerability DatabasePublished
Read the advisory
|
|||||||